Conservator Type Distribution Transformers

Three-phase oil-immersed transformers with oil conservator tank: ratings from 25 kVA to 25,000 kVA, voltage levels up to 6.3 – 11 – 20 – 36 kV, built to TS, IEC, ANSI and BS standards.

Power range
25 kVA – 25,000 kVA
Voltage
6.3 – 11 – 20 – 36 kV
Standards
TS, IEC, ANSI, BS
Yağ genleşme depolu dağıtım trafosu

With years of experience, Plus Transformer produces oil-immersed hermetic distribution transformers from 25 kVA to 25,000 kVA and oil-immersed power transformers from 2.5 MVA to 25 MVA at 66 kV voltage level.

We also take your requests for other transformer types and ratings and offer custom-built transformers.

Technical drawing with numbered parts

Accessories

Accessories and technical data

Accessories used in the production of oil-immersed transformers and their technical data.

Hermetic transformer protection relay

Hermetic transformer protection relay

Preferred for hermetic designs. The relay indicates gas release, oil temperature and the internal pressure of the tank. Used on transformers above 500 kVA. It has two contacts each for gas release, tank pressure and oil temperature.

Alcohol thermometer

Alcohol thermometer

The alcohol thermometer is used only to monitor the transformer oil temperature and has no contacts.

Dehydrating breather

Dehydrating breather

Connected to the oil conservator; when the oil volume changes it captures the moisture in the air passing through it and prevents moisture from entering the oil. Its size depends on the oil and air volume.

Pressure relief valve

Pressure relief valve

Preferred for hermetic designs. Protects the transformer tank against a sudden pressure rise. Mounted on the cover: if the tank reaches the set internal pressure, the valve opens, compensates the pressure by releasing oil and prevents the tank from rupturing, then closes automatically. Available with contacts on request.

Oil temperature thermometer with contacts

Oil temperature thermometer with contacts

Has a maximum pointer showing the highest oil temperature reached, reset with a button at the bottom. Oil temperature can be read up to 120 °C. Two adjustable contacts; micro switch ratings 5 A 250 VAC or 0.2 A 250 VDC.

Magnetic oil level indicator

Magnetic oil level indicator

Used to monitor the oil level in the conservator. Level changes are shown on the gauge via a magnetically coupled float. The setting depends on the conservator diameter; versions with contacts are available on request.

Buchholz relay

Buchholz relay

Piped between the transformer tank and the oil conservator to protect the transformer against faults in its internal electrical equipment. Gas released from insulating materials collects in the chamber and pushes the float down, or a sudden oil surge moves the flap, operating the contacts. Two independent contacts for trip and alarm: 5 A 250 VAC or 0.2 A 250 VDC.

International standards

CountryStandard
TürkiyeTS
InternationalIEC, CENELEC
GermanyVDE
United KingdomBS
USAANSI, NEMA
AustriaÖVE
FranceNF
BelgiumNBN
NetherlandsNEN
DenmarkOS
ItalyOEI
SwedenSEN
NorwayNSAV

Technical specifications

TypeThree-phase, oil-immersed, with oil conservator
Power range25 kVA – 25,000 kVA
Voltage levels6.3 – 11 – 20 – 36 kV
Voltage classes15 kV; 20 kV – 36 kV
StandardsTS, IEC, ANSI, BS (for the requested country voltages)

Technical details

  1. Oil filling hole
  2. Terminal box
  3. Buchholz relay
  4. Thermometer with contact
  5. H.V. bushing
  6. L.V. bushing
  7. Lifting lugs
  8. Oil level indicator
  9. Dehydrating breather
  10. Oil drain valve
  11. Wheels
  12. Rating plate
  13. Alcohol thermometer
  14. Earthing terminal
  15. Off-load tap changer

Production and design options

  • Production for the grid voltages of the requested country
  • Custom production for other transformer types and ratings on request

Quotation

Get a technical quotation for your project

Share the power, voltage and operating conditions; our expert team will prepare the right transformer solution for you.